Common Operation Panel (Cop); Replacing The Cop - Fujitsu PRIMERGY RX4770 M6 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Front panel
14.3

Common operation panel (COP)

14.3.1

Replacing the COP

Field Replaceable Unit
(FRU)
– Phillips PH1 / (+) No. 1 screw driver
Tools:
– Phillips PH2 / (+) No. 2 screw driver (for cover 2)
Note on system information backup/restore
The COP contains the Chassis ID EPROM that contains system information
like server name and model, housing type, serial number and manufacturing
data. To avoid the loss of non-default settings when replacing the system
board, a backup copy of important system configuration data is automatically
stored from the system board NVRAM to the Chassis ID EPROM.
CAUTION
For that reason the COP and the system board must not be replaced
simultaneously! In this case, restoring the system configuration data on
the system board would fail.
Reconfigure the BIOS/iRMC and restore the system information like
server name, server model, housing type, serial number and
manufacturing data manually by Chassis ID Prom Tool.
In case replacing the front panel and system board at the same time, the
system information like server name and model, housing type, serial number
and manufacturing data are not restored automatically. So never forget to
restore it manually by Chassis ID Prom Tool.
Preliminary steps
"Locating the defective server" on page
"Suspending BitLocker functionality" on page
▶ If applicable,
"Removing the front cover with lock" on page
"Shutting down the server" on page
316
46.
Upgrade and Maintenance Manual
Hardware: 35 minutes
Software: 5 minutes
97.
81.
45.
RX4770 M6

Advertisement