Electrical connection
8.3 System integration
Figure 8-8
Table 8- 7
PIN
1
2
3
4
5
6
8.3.8

Power connection

Connection assignment
Table 8- 8
For information on connecting the power, also refer to the diagrams relating to "System
integration". The rotor rotates clockwise if the torque motor is connected to phase sequence
U, V, W. See "Defining the direction of rotation (Page 35)".
166
Pin configuration, M17 signal connector
PIN assignment, M17 signal connector
Interface
-1R2: -KTY or Pt1000
+1R1: +KTY or Pt1000
1TP1: PTC 130 °C
1TP2: PTC 130 °C
-
-
PE
Power connection for torque motor
Converter
U2
V2
W2
Torque motor/stator
U
V
W
Naturally cooled 1FW6 built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE01-0BP3