Requirements For The Motor Supply Cables - Siemens SIMOTICS T-1FW6 Series Configuration Manual

Naturally cooled built-in torgue motors for sinamics s120
Hide thumbs Also See for SIMOTICS T-1FW6 Series:
Table of Contents

Advertisement

Electrical connection
8.3 System integration
8.3.11

Requirements for the motor supply cables

The cables must be appropriately selected corresponding to the mechanical forces caused
by high rates of acceleration and speeds. Further, they must be suitable for the bending
stresses that occur.
Permissible motor feeder cable lengths
The permissible length of the power cable between the motor and the infeed unit depends on
the rated power or the rated output current of the infeed unit.
Example, Motor Module, shielded cable:
up to 50 m power cable length at the rated output current
up to 70 m power cable length at the rated output current 9 A <
up to 100 m power cable length from a rated output current
The permissible signal cable length from the motor to the Control Unit depends on the type
of signal cable being used.
As a result of EMC effects for drive systems, we always recommend that shielded cables are
used.
NOTICE
Damage to cables
Cables subject to high acceleration rates can wear more quickly. The cables permanently
connected to the motor cannot be replaced if they are damaged.
• Observe the permissible acceleration rates for the cables.
• Do not use a drag chain for the cables permanently attached to the motor.
Also refer to the Chapter "System integration". Data on the motor feeder cables, see Chapter
"Data of the power cable at the stator" and catalog.
MOTION-CONNECT cables from the terminal box provided by the customer or extensions
for the power and signal connection, see catalog.
Specification of the motor feeder cables
The built-in torque motors are supplied with MOTION-CONNECT cables according to the
catalog from which you can take the technical data:
Power cable: MOTION-CONNECT 800PLUS, type 6FX8
Signal cable: MOTION-CONNECT 800PLUS, type 6FX8
170
I
≤ 9 A,
n
I
≤ 18 A,
n
I
≥ 30 A
n
Naturally cooled 1FW6 built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE01-0BP3

Advertisement

Table of Contents
loading