10.3

Machine design and adjustment of the phase angle

Each rotation of the mounted rotor induces the 3-phase EMF of the motor in the stator phase
windings. When the master and stoker operate in parallel, the phase angle of each stoker
EMF must match the phase angle of the master EMF.
To adjust the phase angle, the stator and rotor each have a reference mark on their face
sides. The reference marks of the motors are shown in Chapter "Installation drawings/
Dimension drawings (Page 171)".
● The reference mark in the stator depends on the motor article number.
– 1FW6053-xxBxx-0Fxx, 1FW6063-xxBxx-0Fxx, 1FW6063-xxBxx-0Kxx:
– 1FW6053-xxBxx-0Kxx, 1FW6053-xxBxx-1Jxx, 1FW6063-xxBxx-1Jxx:
● The reference mark in the rotor is a centering bore without thread.
1
2
3
4
5
6
Figure 10-1
Naturally cooled 1FW6 built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE01-0BP3
engraved with the letter V
Engraved with the letter Y
Master
Stoker
Stator
Reference mark at the stator (various forms depending on the motor)
Rotor
Reference mark at the rotor
Reference marks for 1FW6 built-in torque motors (schematic)
10.3 Machine design and adjustment of the phase angle