Connection
6.2 Electrical connection
Figure 6-13
Table 6-4
PIN
1
2
3
4
5
6
*) PTC 150 °C, optional in conjunction with KTY 84
6.2.4

Power connection

Table 6-5
Cable protection for motors connected in parallel electrically
For the following configurations, you require a circuit breaker for each motor as conductor
protection:
• Several motors are connected in parallel to one Motor Module.
• The current-carrying capacity of the feeder cable cross-section is less than the rated current
of the Motor Module.
100
Pin configuration, M17 signal connector
PIN assignment, M17 signal connector
Interface
-1R2: -KTY or Pt1000
+1R1: +KTY or Pt1000
1TP1: PTC 130 °C
1TP2: PTC 130 °C
2TP1: PTC 150 °C *)
2TP2: PTC 150 °C *)
PE
Conductor assignment for power cables with open conductor ends
Color/identification
green/yellow
black / U / L1 / C / L+
black / V / L2
black / W / L3 / D / L-
Connection
PE
U
V
W
1FW6 built-in torque motors