3

Fault Repair

3.1

Door Can't Be Closed

Cause:
Locking bolt is in the wrong position (fully integrated models).
Remedy:
Activate the door lock emergency release; see Section 020-4.8.
Cause:
Incorrectly installed stopper at end of top basket guide.
Remedy:
Remove the stopper and install it correctly.
Cause:
Door seal was incorrectly installed and protrudes forward.
Remedy:
Remove the door seal and install it correctly (Section 040-4.1).
Cause:
Damaged door hinges.
Remedy:
Inspect and replace hinges as necessary (see Section 010-4.3).
Cause:
Locking latch is in the wrong position (integrated models).
Remedy:
Press the door lock release.
3.2

Fault with Automatic Door Closing/Opening (LaPerla II)

Symptom:
The closing function of the comfort door closing aid (CTSH) is time-controlled.
As soon as the given time has elapsed, the fault indication Fault with auto.
door closing is displayed. This fault indication can also be displayed if the
door is forcefully slammed shut.
If there is a fault with the opening function, the fault indication Fault
with auto. door opening is displayed.
Cause:
Incorrect operation and/or door closing obstructed.
The time fault can occur, e.g., if a dishtowel between the door and the
cabinet is obstructing the closing action. As soon as the allotted time for
door closing has elapsed, a fault is registered and indicated in the display.
If the door is slammed shut too forcefully, the motorized latch can be forced
out of position causing a fault to be registered (ID nos. -1404, -1465).
Remedy:
The fault is reset by switching the appliance off and on, and then closing the
door correctly.