Miele G 1 Series Technical Information page 127

Hide thumbs Also See for G 1 Series:
Table of Contents

Advertisement

G 1xxx/G 2xxx
7. M24, M6, slide shutter at middle spray arm setting with circulation pump:
The slide shutter is activated and set to the middle spray arm setting. The
circulation pump is then operated for 30 seconds at the maximum speed
for controlled operation. (MPEW and MPPW only.)
8. M24, M6, slide shutter at top/bottom spray arm setting with circulation
pump: The slide shutter is activated and set to the top/bottom spray arm
setting. The circulation pump is then operated for 30 seconds at the
maximum speed for controlled operation. (MPEW and MPPW only.)
9. M24, slide shutter: The slide shutter is activated for 60 seconds. (MPEW
and MPPW only.)
10. Y50, combination dispenser: The combination dispenser is
activated with pulsed operation for 60 seconds. The pulse rhythm
throughout the test period is 10 seconds on/10 seconds off.
11. Y38, Y2, Y5, ... Reactivation sequence (mini-program):
This starts with 30 seconds drainage which begins with pulsed priming (2
seconds on/2 seconds off). The water inlet valve with EGS (electronically
controlled water softener) valve is then activated until 8.3 fluid ounces
(250 milliliters) has been reached or 60 seconds has elapsed. The
reactivation valve is then activated for 150 seconds. Following this the
water inlet valve and the drain pump, which begins with pulsed priming (2
seconds on/2 seconds off), are operated together for 60 seconds.
Warning!
If the reactivation sequence mini-program is started, it must not be
interrupted before it has finished. If it is interrupted, there is a risk that
brine from the SIT could overflow into the cabinet.
12. Y60: Brine valve Y60 is activated for 60 seconds. (Models with SIT only.)
13. Y38, reactivation valve: The reactivation valve is activated for 60
seconds.
14. M2, fan: The fan is activated for 60 seconds.
15. B3/9, M6, circulation pump: The circulation pump is activated for 30
seconds at maximum speed. If the desired speed has not been reached
within 7 seconds, the circulation pump will remain stationary. (MPEW only.)
Warning!
The circulation pump must not run for more than 30 seconds without water.
16. 4N1, M6, wash sequence with middle spray arm sensor (mini-program): This
starts with 30 seconds of drainage which begins with pulsed priming (2 seconds
on/2 seconds off). The water inlet valve is then activated (on models with and
without slide shutter) until 1.4 gallons (5.4 liters) has been taken in. At the same
time the water inlet valve is activated, the slide shutter is set to the middle spray
arm position. The circulation pump with switched auxiliary winding is then
operated. If a spray arm fault is registered during circulation pump operation, the
pump is switched off after 60 seconds; otherwise, it operates for a further 120
127