Fig. 12 Gas mains connection area
Replacement of Burner Injectors
If the injectors are not supplied, contact the Fisher & Paykel Authorised Service Centre. Select the injectors to be
replaced according to the "Table for the Choice of the Injectors".
To Replace the Injectors
Remove pan supports and burners from the cooktop. Using a wrench substitute the nozzle injectors with those most
suitable for the kind of gas for which it is to be used. The burners are designed so that adjustment of primary air is not
required.
https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR90LDBGFX3/User_Guide_OR90LDBGFX...
Updated: Fri, 10 Apr 2020 07:18:41 GMT
Powered by
10