6

Start up

6.1

Check before starting up

Before starting up, ensure that
-
all regulations for explosion proof are kept to,
-
all connections have been properly made, and the plug connectors are secured against
loose,
-
all motor protections devices are active,
-
the drive is not blocked,
-
no other possible sources of danger are present,
-
the drive is undamaged (no damage from transport/storage),
-
the feather keys in the shaft end (if present) are secured against being thrown out.
6.2

Start

The output elements have to be connected non-positive to the shaft end
(slip-danger by shaft end without key).
Observe the start up and commissioning instructions for the converter
(e.g. MASTERDRIVES MC) and check the direction of rotation.
Installation only by qualified personnel.
Siemens AG
Thermal hazard from hot surface! The surface temperatures of the
motors can reach up to 140 °C (284 °F).
Do not touch hot surfaces!
Protection must be provided against accidental contact if necessary.
TEMPERATURE-SENSITIVE COMPONENTS (ELECTRIC LINES,
ELECTRONIC COMPONENTS) MUST NOT TOUCH HOT SURFES.
Hazard from rotating rotor!
Protect the output elements against accident contact!
Secure feather key (if present) against thrown out.