For the operation the internal PTC (DIN 44082) must be connected to an external and
valided cut-off device.
-
In case of loss of the original screws are only certificated screws permitted.
-
The used connecting line have to be certificated for an operation temperature of 100°C
(212°F).
-
If the motor is supplied by means of converters, high-frequency current and voltage
harmonics in the motor supply leads can cause electromagnetic interference to be
emitted. Use shielded power and signal lines. Observe the EMC instructions of the
converter manufacurer.
-
Avoid protruding wire ends.
Power connection
Fig. 4 Pinning power terminal box for:
1FS6074
Encoder signal
The minimum cross section of the terminal in the encoder
terminal box is 0,5 mm².
The standard connection line is 0,14 mm² only. => Set wire sockets.