Instruction
Byte AND
If EN = 1,
Byte OR
b = a AND b
Byte XOR
b = a OR b
b = a XOR b
Word AND
If EN = 1,
Word OR
b = a AND b
Word XOR
b = a OR b
b = a XOR b
DWord AND
If EN = 1,
DWord OR
b = a AND b
DWord XOR
b = a OR b
b = a XOR b
Invert Byte
If EN = 1,
a = /a
Invert Word
If EN = 1,
a = /a
Invert DWord
If EN = 1,
a = /a
LOGIC OPERATIONS
Ladder Symbol
WAND_B
EN
ENO
IN1
OUT
IN2
WAND_W
EN
ENO
IN1
OUT
IN2
WXOR_DW
EN
ENO
IN1
OUT
IN2
INV_B
EN
ENO
OUT
IN
INV_W
EN
ENO
OUT
IN
INV_DW
EN
ENO
OUT
IN
Valid Operands
Enable:
EN
In:
VB, IB, QB, MB, AC,
Constant, LB
Out: VB, IB, QB, MB, AC, LB
Enable:
EN
In:
VW, T, C, IW, QW, MW,
AC, Constant, LW
Out: VW, T, C, IW, QW, MW,
AC, LW
Enable:
EN
In:
VD, ID, QD, MD, AC,
Constant, LD
Out: VD, ID, QD, MD, AC, LD
Enable:
EN
In:
VB, IB, QB, MB, AC,
Constant, LB
Out: VB, IB, QB, MB, AC, LB
Enable:
EN
In:
VW, T, C, IW, QW, MW,
AC, Constant, LW
Out: VW, T, C, IW, QW, MW,
AC, LW
Enable:
EN
In:
VD, ID, QD, MD, AC,
Constant, LD
Out: VD, ID, QD, MD, AC, LD