Installing the Control System
2-18
Pin
Name
1
n.c.
2
DI24
3
DI25
4
DI26
5
DI27
6
DI28
7
DI29
8
DI30
9
DI31
10
M
Pin
Name
1
n.c.
2
DI32
3
DI33
4
DI34
5
DI35
6
DI36
7
DI37
8
DI38
9
DI39
10
M
Pin
Name
1
n.c.
2
DI40
3
DI41
4
DI42
5
DI43
6
DI44
7
DI45
8
DI46
9
DI47
10
M
Signal names
DI0...47
24 V digital inputs
Signal type
VI
Voltage input
DI
Input (24 V signal)
Table 2–14 Electrical parameters of the digital inputs
Parameter
"1" signal, voltage range
"1" signal, current consumption
"0" signal, voltage range
Signal delay 0 Æ 1
Signal delay 1 Æ 0
X103
Type
X103
DI
24
DI
25
DI
26
27
DI
28
DI
29
30
DI
31
DI
M
DI
VI
X104
Type
X104
DI
DI
32
33
DI
34
DI
35
36
DI
37
DI
38
DI
39
M
DI
VI
X105
Type
X105
DI
40
DI
41
DI
42
DI
43
44
DI
45
DI
46
DI
47
M
DI
VI
Value
15...30
2...15
–3...5
0.5...3
0.5...3
Unit
Note
V
mA
V
or input open
ms
ms