Zh078-150 Cooling Capacities - Zh150 (12.5 Ton) - York PREDATOR R-410A Technical Manual

R-410a zh/zr/xp series 6-1/2 - 12-1/2 ton 60 hertz
Table of Contents

Advertisement

246824-YTG-G-1208
ZH150 (12.5 Ton)
Air on
Evaporator Coil
Total
1
Capacity
WB
CFM
(MBh)
(°F)
77
187.0
72
176.3
3125
67
165.5
62
149.3
77
193.7
72
182.5
3750
67
171.4
62
154.5
57
155.4
77
200.3
72
188.8
4375
67
177.2
62
159.8
57
160.7
77
207.0
72
195.1
5000
67
183.1
62
165.1
57
166.0
72
203.6
67
191.1
5625
62
172.4
57
173.3
72
212.2
67
199.1
6250
62
179.6
57
180.6
77
178.3
72
163.6
3125
67
148.9
62
136.0
77
183.6
72
168.4
3750
67
153.3
62
140.1
57
141.1
77
188.9
72
173.3
4375
67
157.7
62
144.1
57
145.2
77
194.1
72
178.1
5000
67
162.1
62
148.1
57
149.2
72
183.1
67
166.6
5625
62
152.2
57
153.4
72
188.0
67
171.1
6250
62
156.3
57
157.5
30
Sensible Capacity (MBh)
Total
Input
Return Dry Bulb (°F)
2
(kW)
90
85
80
75°F
9.5
73.2
60.2
47.2
9.5
98.5
85.5
72.4
9.4
123.7
110.7
97.7
9.2
149.3
143.1
119.8
9.6
82.5
67.3
52.2
9.6
110.4
95.2
80.1
9.5
138.3
123.1
108.0
9.3
154.5
150.5
132.4
9.2
155.4
155.4
138.2
9.7
91.7
74.4
57.2
9.7
122.3
105.0
87.7
9.6
152.8
135.5
118.2
9.3
159.8
157.8
145.0
9.3
160.7
160.7
151.3
9.8
101.0
81.6
62.2
9.8
134.2
114.7
95.3
9.7
167.3
147.9
128.5
9.4
165.1
165.1
157.6
9.4
166.0
166.0
164.4
9.7
143.3
122.5
101.8
9.6
183.2
158.0
137.2
9.4
172.4
172.4
168.6
9.3
173.3
173.3
172.5
9.7
152.4
130.3
108.2
9.6
199.1
168.0
145.9
9.4
179.6
179.6
179.6
9.3
180.6
180.6
180.6
95°F
11.7
76.0
62.2
48.4
11.6
98.8
85.0
71.3
11.5
121.6
107.9
94.1
11.2
136.0
136.0
117.1
11.8
83.7
68.2
52.7
11.7
108.6
93.1
77.6
11.6
133.4
117.9
102.4
11.3
140.1
140.1
127.5
11.3
141.1
141.1
128.2
12.0
91.5
74.2
57.0
11.8
118.3
101.1
83.9
11.7
145.2
128.0
110.7
11.4
144.1
144.1
137.8
11.4
145.2
145.2
138.6
12.1
99.2
80.3
61.3
11.9
128.1
109.1
90.1
11.8
157.0
138.0
119.0
11.5
148.1
148.1
148.1
11.5
149.2
149.2
148.9
11.9
138.0
117.4
96.9
11.8
164.0
148.5
128.0
11.5
152.2
152.2
152.2
11.5
153.4
153.4
153.2
11.9
147.8
125.7
103.7
11.8
171.1
159.0
136.9
11.5
156.3
156.3
156.3
11.5
157.5
157.5
157.5
Temperature of Air on Condenser Coil
Total
1
Capacity
(MBh)
75
70
65
-
-
-
182.7
59.4
-
-
169.9
84.7
71.7
-
157.2
106.8
93.8
80.8
142.6
-
-
-
188.6
64.9
-
-
175.5
92.8
77.7
-
162.3
117.3
102.1
87.0
147.3
123.1
107.9
92.8
148.3
-
-
-
194.6
70.4
-
-
181.0
101.0
83.7
-
167.5
127.7
110.5
93.2
152.0
134.0
116.8
99.5
152.9
-
-
-
200.6
75.9
-
-
186.6
109.1
89.7
-
172.6
138.2
118.8
99.4
156.6
145.0
125.6
106.2
157.6
81.1
-
-
193.3
116.5
95.8
-
178.9
147.9
127.1
106.4
162.3
151.8
131.0
110.3
163.3
86.2
-
-
200.1
123.9
101.8
-
185.1
157.5
135.5
113.4
168.0
158.5
136.5
114.4
169.0
-
-
-
167.8
57.5
-
-
153.7
80.3
66.6
-
139.7
103.4
89.6
75.8
128.6
-
-
-
172.5
62.1
-
-
158.0
86.9
71.4
-
143.6
112.0
96.5
81.0
132.2
112.7
97.2
81.6
132.5
-
-
-
177.2
66.6
-
-
162.3
93.5
76.2
-
147.5
120.6
103.3
86.1
135.8
121.3
104.1
86.8
136.1
-
-
-
181.9
71.2
-
-
166.6
100.0
81.0
-
151.4
129.2
110.2
91.2
139.4
130.0
111.0
92.0
139.7
76.4
-
-
170.9
107.4
86.9
-
155.3
131.7
111.2
90.7
143.0
132.7
112.2
91.6
143.3
81.6
-
-
175.1
114.8
92.8
-
159.1
134.3
112.2
90.1
146.5
135.4
113.4
91.3
146.8
Sensible Capacity (MBh)
Total
Input
Return Dry Bulb (°F)
2
(kW)
90
85
80
85°F
10.6
74.6
61.2
47.8
10.5
98.6
85.2
71.9
10.4
122.7
109.3
95.9
10.2
142.6
139.6
118.5
10.7
83.1
67.8
52.4
10.6
109.5
94.1
78.8
10.5
135.8
120.5
105.2
10.3
147.3
145.3
129.9
10.3
148.3
148.3
133.2
10.8
91.6
74.3
57.1
10.7
120.3
103.0
85.8
10.6
149.0
131.7
114.5
10.4
152.0
151.0
141.4
10.4
152.9
152.9
144.9
10.9
100.1
80.9
61.7
10.8
131.1
111.9
92.7
10.7
162.2
143.0
123.8
10.5
156.6
156.6
152.9
10.5
157.6
157.6
156.7
10.8
140.6
120.0
99.4
10.7
173.6
153.2
132.6
10.5
162.3
162.3
160.4
10.4
163.3
163.3
162.9
10.8
150.1
128.0
106.0
10.7
185.1
163.5
141.4
10.4
168.0
168.0
168.0
10.4
169.0
169.0
169.0
105°F
13.1
69.9
58.4
44.7
13.0
94.5
80.9
67.2
12.8
119.1
103.4
89.7
12.6
128.6
128.6
108.9
13.2
79.8
64.4
48.9
13.0
104.4
89.0
73.5
12.9
129.0
113.6
98.1
12.7
132.2
132.2
119.0
12.7
132.5
132.5
119.2
13.3
89.7
70.4
53.1
13.1
114.3
97.1
79.8
13.0
138.9
123.8
106.5
12.8
135.8
135.8
129.2
12.8
136.1
136.1
129.4
13.3
99.7
76.3
57.3
13.2
124.2
105.2
86.1
13.1
148.8
134.0
114.9
12.9
139.4
139.4
139.4
12.9
139.7
139.7
139.6
13.2
133.8
113.2
92.7
13.1
154.0
143.5
123.7
12.9
143.0
143.0
143.0
12.9
143.3
143.3
143.2
13.2
143.4
121.3
99.2
13.1
159.1
153.1
132.5
12.9
146.5
146.5
146.5
12.9
146.8
146.8
146.8
Johnson Controls Unitary Products
75
70
65
-
-
-
58.5
-
-
82.5
69.1
-
105.1
91.7
78.3
-
-
-
63.5
-
-
89.9
74.5
-
114.6
99.3
84.0
117.9
102.5
87.2
-
-
-
68.5
-
-
97.2
80.0
-
124.2
106.9
89.6
127.7
110.4
93.2
-
-
-
73.5
-
-
104.6
85.4
-
133.7
114.5
95.3
137.5
118.3
99.1
78.7
-
-
112.0
91.3
-
139.8
119.2
98.5
142.2
121.6
101.0
83.9
-
-
119.3
97.3
-
145.9
123.8
101.8
147.0
124.9
102.8
-
-
-
53.6
-
-
76.1
62.4
-
95.2
81.5
67.9
-
-
-
58.1
-
-
82.7
67.2
-
103.6
88.1
72.7
103.7
88.3
72.8
-
-
-
62.5
-
-
89.3
72.0
-
112.0
94.7
77.4
112.1
94.8
77.6
-
-
-
67.0
-
-
95.9
76.8
-
120.3
101.3
82.2
120.5
101.4
82.4
72.1
-
-
103.1
82.5
-
122.4
101.8
81.2
122.6
102.0
81.5
77.1
-
-
110.4
88.3
-
124.4
102.3
80.3
124.7
102.7
80.6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents