York PREDATOR R-410A Technical Manual page 61

R-410a zh/zr/xp series 6-1/2 - 12-1/2 ton 60 hertz
Table of Contents

Advertisement

XP150 (12.5 Ton) (Continued)
Air on
Evaporator Coil
Total
1
Capacity
WB
CFM
(MBh)
(°F)
77
139.5
72
131.8
3125
67
124.1
62
118.9
77
143.6
72
135.7
3750
67
127.8
62
122.4
57
120.6
77
147.7
72
139.6
4375
67
131.5
62
125.9
57
124.1
77
151.8
72
143.5
5000
67
135.1
62
129.4
57
127.6
72
147.4
67
138.8
5625
62
133.0
57
131.0
72
151.3
67
142.5
6250
62
136.5
57
134.5
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
Johnson Controls Unitary Products
Sensible Capacity (MBh)
Total
Input
Return Dry Bulb (°F)
2
(kW)
90
85
80
115°F
14.4
52.0
44.1
30.8
14.2
84.1
70.7
57.4
14.1
116.1
97.4
84.0
14.0
118.9
117.5
97.0
14.4
64.1
48.9
33.7
14.3
93.3
78.1
62.9
14.1
122.5
107.2
92.0
14.0
122.4
121.5
106.2
14.1
120.6
120.6
108.1
14.5
76.2
53.7
36.6
14.3
102.5
85.4
68.3
14.1
128.8
117.1
100.0
14.1
125.9
125.4
115.4
14.1
124.1
124.1
117.4
14.5
88.3
58.5
39.5
14.3
111.7
92.7
73.7
14.2
135.1
127.0
108.0
14.1
129.4
129.4
124.6
14.1
127.6
127.6
126.8
14.4
119.1
98.9
78.8
14.2
138.8
134.7
115.3
14.1
133.0
133.0
130.6
14.1
131.0
131.0
130.7
14.4
126.5
105.2
83.8
14.2
142.5
142.5
122.7
14.2
136.5
136.5
136.5
14.2
134.5
134.5
134.5
Temperature of Air on Condenser Coil
Total
1
Capacity
(MBh)
75
70
65
-
-
-
131.7
44.1
-
-
123.5
70.7
57.4
-
115.3
83.7
70.3
57.0
111.7
-
-
-
135.2
47.6
-
-
126.8
76.8
61.6
-
118.4
91.0
75.8
60.6
114.7
92.8
77.6
62.4
113.3
-
-
-
138.8
51.2
-
-
130.1
82.9
65.8
-
121.5
98.3
81.2
64.1
117.8
100.3
83.2
66.1
116.3
-
-
-
142.3
54.8
-
-
133.5
89.0
70.0
-
124.6
105.7
86.7
67.7
120.8
107.8
88.8
69.8
119.2
58.6
-
-
137.3
95.2
75.0
-
128.1
110.4
90.2
70.1
124.2
110.5
90.3
70.1
122.6
62.5
-
-
141.1
101.3
80.0
-
131.7
115.2
93.8
72.5
127.6
113.2
91.8
70.5
126.0
246824-YTG-G-1208
Sensible Capacity (MBh)
Total
Input
Return Dry Bulb (°F)
2
(kW)
90
85
80
125°F
15.8
47.4
40.6
27.0
15.6
81.4
67.8
54.2
15.4
115.3
95.0
81.4
15.4
111.7
110.5
89.9
15.8
62.4
45.1
29.5
15.6
90.4
74.8
59.3
15.4
118.4
104.6
89.1
15.4
114.7
114.0
98.4
15.4
113.3
113.3
101.2
15.8
77.3
49.6
32.1
15.6
99.4
81.9
64.4
15.4
121.5
114.2
96.7
15.4
117.8
117.4
106.9
15.4
116.3
116.3
109.9
15.9
92.2
54.1
34.6
15.6
108.4
89.0
69.5
15.4
124.6
123.8
104.4
15.4
120.8
120.8
115.3
15.4
119.2
119.2
118.6
15.7
116.2
95.3
74.5
15.5
128.1
128.1
111.9
15.5
124.2
124.2
121.5
15.5
122.6
122.6
122.3
15.7
123.9
101.7
79.5
15.5
131.7
131.7
119.4
15.5
127.6
127.6
127.6
15.5
126.0
126.0
126.0
75
70
65
-
-
-
40.6
-
-
67.8
54.2
-
76.4
62.8
49.2
-
-
-
43.7
-
-
73.5
58.0
-
82.9
67.3
51.8
85.6
70.1
54.6
-
-
-
46.9
-
-
79.2
61.7
-
89.4
71.9
54.4
92.4
74.9
57.4
-
-
-
50.0
-
-
84.9
65.5
-
95.9
76.4
57.0
99.1
79.7
60.2
53.7
-
-
91.0
70.2
-
100.7
79.8
59.0
101.5
80.6
59.8
57.3
-
-
97.2
74.9
-
105.4
83.2
61.0
103.8
81.6
59.4
61