TABLE 5: COOLING CAPACITIES - 3 TON (DEE / DEG036)
AIR ON
EVAPORATOR
COIL
TOTAL
POWER
1
CAP.
WB
MBH
CFM
°F
72
55
67
52
1500
62
42
57
42
72
51
67
49
1350
62
39
57
40
72
48
67
46
1200
62
36
57
37
72
46
67
44
1050
62
35
57
36
72
45
67
42
900
62
34
57
35
AIR ON
EVAPORATOR
COIL
TOTAL
POWER
.1
CAP
WB
MBH
CFM
°F
72
47
67
44
1500
62
36
57
36
72
44
67
42
1350
62
34
57
34
72
42
67
40
1200
62
32
57
32
72
40
67
38
1050
62
30
57
31
72
38
67
36
900
62
29
57
30
1.
These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from Table 8 or 11, multiply
this value by 3.425 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
2.
These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan
motor power input is 0.36kW. Refer to Table 8 or 11 for the kW of the supply air blower motor.
NOMINAL RATING
8
TEMPERATURE OF AIR ON CONDENSER COIL
85°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
INPUT
kW
86
83
80
77
3.4
35
31
26
22
3.3
47
42
38
33
3.2
42
42
42
37
3.2
42
42
42
38
3.3
32
28
24
20
3.3
42
38
34
30
3.2
39
39
37
33
3.2
40
40
38
34
3.2
28
24
21
17
3.3
37
34
30
27
3.2
36
36
33
29
3.2
37
37
35
31
3.3
26
23
19
16
3.3
34
31
28
25
3.2
35
34
31
28
3.2
36
35
32
29
3.3
24
21
18
15
3.2
31
29
26
23
3.2
34
32
26
26
3.1
35
33
30
27
TEMPERATURE OF AIR ON CONDENSER COIL
105°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
INPUT
kW.
86
83
80
77
3.9
33
29
25
20
3.8
43
39
35
30
3.7
36
36
36
31
3.7
36
36
36
31
3.9
30
26
22
18
3.8
39
36
32
28
3.7
34
34
33
29
3.7
34
34
34
30
3.8
27
23
20
16
3.8
36
32
29
25
3.7
32
32
31
28
3.7
32
32
33
29
3.8
24
21
18
15
3.7
32
29
26
23
3.7
30
30
28
25
3.6
31
31
30
27
3.8
22
19
16
13
3.7
29
26
23
20
3.6
29
28
26
23
3.6
30
29
27
24
1
, MBH
TOTAL
POWER
.1
CAP
INPUT
MBH
kW.
74
71
68
18
-
-
51
29
24
20
48
33
28
24
39
33
29
24
39
16
-
-
49
26
22
18
47
29
25
21
37
30
26
22
38
14
-
-
48
23
19
16
46
26
22
19
36
27
24
20
37
13
-
-
45
22
18
15
43
24
21
18
34
26
23
20
35
13
-
-
43
20
17
15
40
23
20
18
32
25
22
19
33
1
, MBH
TOTAL
POWER
.1
CAP
INPUT
MBH
kW.
74
71
68
16
-
-
43
26
22
17
40
27
22
18
33
27
23
18
33
14
-
-
39
24
20
16
37
25
21
17
30
26
22
18
30
12
-
-
36
22
18
14
34
24
20
17
27
26
22
19
28
12
-
-
35
19
16
13
33
22
19
16
27
24
20
17
27
11
-
-
34
17
15
12
32
20
17
15
26
21
19
16
26
ALL SENSIBLE CAPACITY
036-21411-002-A-0204
95°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
3.7
35
30
26
21
3.6
45
41
36
32
3.5
39
39
39
34
3.5
39
39
39
35
3.6
32
28
24
20
3.5
42
38
34
30
3.5
37
37
37
33
3.5
38
38
38
34
3.6
29
25
22
18
3.5
39
36
32
38
3.5
36
36
35
31
3.4
37
37
37
33
3.6
26
23
20
16
3.5
35
32
28
25
3.4
34
33
31
28
3.4
35
34
33
30
3.5
23
20
17
15
3.5
30
28
25
22
3.4
32
30
28
25
3.4
33
32
29
26
115°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
4.1
32
28
23
19
4.1
40
38
33
29
4.0
33
33
33
28
3.9
33
33
33
28
4.1
28
24
20
16
4.0
36
33
29
25
4.0
30
30
30
26
3.9
30
30
31
27
4.1
24
21
17
14
4.0
33
29
25
22
3.9
27
27
28
24
3.9
28
28
29
26
4.1
22
19
16
13
4.0
30
26
23
20
3.9
27
27
26
22
3.9
27
27
27
24
4.0
20
18
15
12
4.0
27
24
21
18
3.9
26
26
24
21
3.9
26
26
25
22
Unitary Products Group
1
, MBH
74
71
68
17
-
-
28
23
19
30
25
21
30
26
21
16
-
-
26
22
18
29
25
21
30
26
22
15
-
-
25
21
18
28
24
21
30
26
22
13
-
-
22
19
16
25
22
19
27
23
20
12
-
-
19
16
14
22
19
17
24
21
18
1
, MBH
74
71
68
14
-
-
24
20
16
24
19
15
24
20
15
12
-
-
21
17
13
22
18
14
23
19
15
10
-
-
18
15
11
20
17
13
22
18
15
10
-
-
17
14
11
19
16
13
21
17
14
9
-
-
16
13
10
18
15
13
19
17
14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents