Burner Models: Wayne P265-EP
Fuels: Natural or L.P. Gases
Electrical: 120 V.A.C., 60 Hz, 1 ph
NOTE: Orifice and valve setting must correlate with type of gas being supplied.
Firing Capacity
Firing Rate Btu
65,000
KW
SRG-400
Pilot Orifice Size Chart
Natural
BCR-24
LP
BCR-18
BURNER SPECIFICATIONS
19
Natural
X
LP
Knob must be in ON (vertical) position.
Gas Supply Line Pressure
Minimum
Maximum
4.5" w.c.
10.0" w.c.
11.2 mbar
24.9 mbar
11.0" w.c.
13.0" w.c.
27.4 mbar
32.4 mbar
Main Orifice Size Chart
65,000 Btu/hr
Natural Gas
19 KW/hr
65,000 Btu/hr
19 KW/hr
Gas Valve
Supply gas pressure
16 of 36
Copyright 2019 by Southern Pride Distributing, LLC Revision 5
Manifold Pressure
Minimum
3.0" w.c.
7.5 mbar
9.5" w.c.
23.7 mbar
#26 (.147")
(3.73mm)
#43 (.089")
LP Gas
(2.26mm)
test port
Maximum
3.5" w.c.
8.7 mbar
10.0" w.c.
24.9 mbar