Electrical Instructions - Southern Pride SRG-400 Owner's Manual

Gas-fired wood-burning stationary rack bbq smoker
Hide thumbs Also See for SRG-400:
Table of Contents

Advertisement

Electrical Requirements:
120 volts AC, 60 Hz
2 wire, single phase
15 amp required, NEMA 5-15P plug
THE WARRANTY IS VOID IF THE SMOKER IS CONNECTED TO ANY VOLTAGE OTHER
THAN SPECIFIED ABOVE AND ON THE SMOKER DATA PLATE.
Remove all packing material before connecting the electrical and gas supply to the smoker.
An electrician must provide the conduit and wire for electrical hookup. The smoker should be connected

to a dedicated 15 amp receptacle.
The power is to be left OFF throughout the installation.

The electrical service is connected via the factory supplied power cord located on the rear of the smoker on

the service bay side. Alternatively, the power cord can be removed and the smoker hard wired.
If venting or gas connections are to be done at a later time, be sure that the power remains OFF.

The restraining device must be installed.

Electrical Connection
Tether Connection
Gas Supply Connection

ELECTRICAL INSTRUCTIONS

10 of 36
WARNING:
This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.2, as applicable.
Copyright 2019 by Southern Pride Distributing, LLC Revision 5