Error Codes - 4-Way Cassette Indoor Unit - Bosch Climate 5000 Series Service Manual

Ductless air conditioner / heat pump outdoor unit
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Service Manual

6.2 Error Codes - 4-Way Cassette Indoor Unit

Number
Cause
1
Indoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error
2
Indoor and outdoor unit communication malfunction
3
Indoor fan speed malfunction
4
Indoor room temperature sensor error
5
Evaporator coil temperature sensor error
6
Refrigerant leak detection system malfunction
7
Water level alarm malfunction
8
Dual indoor unit (twin model only) communication malfunction
9
Other twin model malfunction
10
Overload protection
11
Outdoor temperature sensor error
12
Outdoor condenser pipe sensor error
13
Discharge air temperature sensor error
14
Outdoor EEPROM (Electrically Erasable Programmable Read-Only Memory) error
15
Outdoor fan speed (DC fan motor only) malfunction
16
Auto-lifting panel communication error
17
Auto-lifting panel malfunction
18
Auto-lifting panel is open
19
Inverter module IPM protection
20
High/Low voltage protection
21
Compressor top overheating protection
22
Outdoor low temperature protection
23
Compressor drive error
24
Mode con ict
25
Compressor low-pressure protection
26
Outdoor IGBT sensor error
Table 13
9k~18k models do not have display to show error codes and Operation
and Timer Indicator will turn on / off and or ash according to above
table to show system malfunction.
Bosch Thermotechnology Corp. | 04.2020
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit | 19
Operation indicator
ashes
1
2
4
5
6
7
8
9
10
1
2
3
4
5
6
8
9
10
1
2
3
4
5
6
7
8
Timer indicator
Error Code
Off
E0
Off
E 1
Off
E3
Off
E4
Off
E5
Off
EC
Off
EE
Off
E8
Off
E9
On
F0
On
F 1
On
F2
On
F3
On
F4
On
F5
On
F7
On
F8
On
F9
Flash
P0
Flash
P 1
Flash
P2
Flash
P3
Flash
P4
Flash
P5
Flash
P6
Flash
P7
Data subject to change

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents