Ductless air conditioner / heat pump outdoor unit
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Service Manual
7.1.2 PCB: Regular Single Zone 9K & 12K
BMS500-AAS009-1CSXRA, BMS500-AAS009-1CSXXA, BMS500-AAS012-
1CSXRA, BMS500-AAS012-1CSXXA
Figure 13
Number
Name
1
Power Supply
2
S
3
HEAT1
4
4-WAY
5
HEAT2
6
AC-FAN
7
TP T4 T3
8
TP T4 T3
9
PMV
10
DC-FAN
11
FAN_IPM
12
TESTPORT
13
EE_PORT
14
MCUPORT
W
15
V
U
16
COMP_IPM
17
CN9
18
CN32
Table 17
Bosch Thermotechnology Corp. | 04.2020
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit | 23
CN#
Description
CN3
Earth: connect to Ground
CN1
N_in: connect to N-line (208-230V AC input)
CN2
L_in: connect to L-line (208-230V AC input)
CN16
S: connect to indoor unit communication
CN17
connect to compressor heater, 208-230V AC when ON
CN60
connect to 4 way valve, 208-230V AC when ON.
CN15
connect to chassis heater, 208-230V AC when ON
CN25
connect to AC fan
CN22
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust temp. sensor TP
CN21
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust temp. sensor TP
CN31
connect to Electric Expansion Valve
CN7
connect to DC fan
IPM 501
IPM for DC fan
CN6
used for testing
CN505
EEPROM programmer port
CN507
connect to PC communication
CN28
connect to compressor
CN29
0V AC (standby)
CN30
10-200V AC (running)
IPM 301
IPM for compressor
CN9
connect to reactor
CN32
connect to reactor