Bosch Climate 5000 Series Service Manual page 24

Ductless air conditioner / heat pump outdoor unit
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

2 4 | Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit
7.1.3 PCB: Regular Single Zone 18K & 24K
BMS500-AAS018-1CSXRA, BMS500-AAS018-1CSXXA, BMS500-AAS024-1CSXRA, BMS500-AAS024-1CSXXA
7.1.4 PCB: Hyper Heat Single Zone 9K, 12K & 18K
BMS500-AAS009-1CSXHB, BMS500-AAS012-1CSXHB, BMS500-AAS018-1CSXHB
Figure 14
Number
Name
1
Power Supply
2
S
3
4-WAY
4
HEAT1
5
AC-FAN
6
HEAT2
7
CN38
8
PMV
9
DC-FAN
10
FAN_IPM
11
CN19
12
TESTPORT
13
CN9
U
14
V
W
15
COMP_IPM
Table 18
Data subject to change
CN#
Description
CN3
Earth: connect to Ground
CN7
N_in: connect to N-line (208-230V AC input)
CN8
L_in: connect to L-line (208-230V AC input)
CN3
S: connect to indoor unit communication
CN60
connect to 4 way valve, 208-230V AC when is ON.
CN17
connect to compressor heater, 208-230V AC when is ON
CN11
connect to AC fan
CN16
connect to chassis heater, 208-230V AC when is ON
CN38
connect to PC communication
CN18
connect to Electric Expansion Valve
CN414
connect to DC fan
IPM 501
IPM for DC fan
CN19
internal drive motor
CN23
used for testing
CN9
connect to PC communication
CN28
connect to compressor
CN29
0V AC (standby)
CN30
10-200V AC (running)
IPM 301
IPM for compressor
Service Manual
04.2020 | Bosch Thermotechnology Corp.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents