Service Manual
T3,T4,T5,sensor
Pressure switch
Electronic expansion
Figure 121
4.
Disconnect the connector for the fan motor from the electronic control board.
Figure 122
5.
Remove the four af xing screws of the fan motor. Then remove the fan motor.
Figure 123
Bosch Thermotechnology Corp. | 04.2020
Compressor
wire
Reversing valve
Motor wire
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit | 85
9.6.3 Removing the electrical parts
1.
After removing the panel plate and fan assembly, remove the connector for
the compressor.
Figure 124
2.
Pull out the two blue wires connected with the reversing valve.
Figure 125
3.
Pull out connectors of the condenser coil temp. sensor (T3), outdoor
ambient temp. sensor (T4) and discharge temp. sensor (T5).
Figure 126
Data subject to change