Bosch Climate 5000 Series Service Manual page 74

Ductless air conditioner / heat pump outdoor unit
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

7 4 | Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit
4.
Disconnect the connector for fan motor from the electronic control board.
Figure 74
5.
Remove the four af xing screws of the fan motor, then remove the motor.
Figure 75
Data subject to change
9.1.3 Removing the electrical parts
1.
After removing the panel plate and fan assembly, remove the connector for
the compressor.
Figure 76
2.
Pull out the two blue wires connected with the four way valve.
Figure 77
3.
Pull out connectors of the condenser coil temp. sensor (T3), outdoor
ambient temp. sensor (T4) and discharge temp. sensor (T5).
Figure 78
Service Manual
04.2020 | Bosch Thermotechnology Corp.

Hide quick links: