7 0 | Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit
Compressor check
Measure the resistance value of each winding by using the tester.
Figure 66
Position
115V - 12K
Blue - Red
Blue - Black
2.25
Red - Black
Table 47
36K Light
Position
Commercial
Cassette &
Ducted
Blue - Red
Blue - Black
0.65
Red - Black
Table 48
Data subject to change
9K
12K
Regular
Regular
1.57
2.25
48K Light
60K Light
Commercial
Commercial
0.38
0.38
Figure 67
Resistance Value
18K
24K
Regular
Regular
1.75
0.75
Resistance Value
9K
12K
Hyper Heat
Hyper Heat
1.87
1.87
Service Manual
36K Light
30K Light
Commercial
Commercial
Wall Mounted
0.75
0.75
18K
24K
Hyper Heat
Hyper Heat
0.75
0.75
04.2020 | Bosch Thermotechnology Corp.