Cooling Method; Temperature Monitoring And Thermal Motor Protection; Temperature Monitoring Circuits Temp-S And Temp-F - Siemens SIMOTICS T-1FW6 Series Configuration Manual

High speed built-in torque motors
Hide thumbs Also See for SIMOTICS T-1FW6 Series:
Table of Contents

Advertisement

Motor components and options
4.1 Motor components
4.1.1.3

Cooling method

The stator in the built-in torque motors is equipped with a liquid cooler for dissipating heat
loss.
The cooling method used depends on the size (external diameter) of the motor as follows.
Table 4- 1
Frame size
1FW6092
1FW6132
1FW6152
1FW6192
1FW6232
4.1.2

Temperature monitoring and thermal motor protection

4.1.2.1

Temperature monitoring circuits Temp-S and Temp-F

The motors are equipped with the two temperature monitoring circuits – Temp-S and Temp-F
– that are described below.
● Temp-S activates the thermal motor protection when the motor windings are thermally
overloaded. In this case the precondition is that Temp-S is correctly connected and
evaluated. For a thermal overload, the drive system must bring the motor into a no-
current condition.
● Temp-F is used for temperature monitoring and diagnostics during commissioning and in
operation.
Both temperature monitoring circuits are independent of one another.
For example, the SME12x Sensor Module or the TM120 Terminal Module evaluates the
temperature sensor signals.
You can obtain commissioning information from Technical Support. Contact data is provided
in the introduction.
72
Cooling method
Cooling jacket
X
X
X
Integrated cooling
with two cooling circuits
(main cooler and precision cooler)
X
X
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3

Advertisement

Table of Contents
loading

Table of Contents