8
Technical Information
Profibus Option
OFFSET
SIZE
UNIT RES
BYTE
BYTE
21
1
172/190
RANGE
DESCRIPTION
B
= Gas Load Type. Select here the gas load
1
0 = Ar
1 = N2
B
= Interlock Type
2
0 = continuos (the interlock must be always present
to run the pump)
1 = at start (the interlock must be present only at
start command)
B
= Setpoint R1 Logic
3
0 = active close (NO)
1 = active open (NC)
B
= Setpoint R2 Logic
4
0 = active close (NO)
1 = active open (NC)
B
-
5
6
0 = mbar
1 = Pascal
2 = Torr
B
= Reserved
7
B
-
0
2
0 = frequency
1 = current
2 = time
3= normal operation
4= pressure
B
3-5
0 = frequency
1 = current
2 = time
3= normal operation
4= pressure
B
-
6
7
0 = frequency
1 = power
2 = temperature
3= pressure
TwisTorr 305 FS Remote Controller User Manual / 87-901-059-01
= Pressure Unit
= Setpoint R1 Type
= Setpoint R2 Type
= Analog Output 1 Type