Product Space & Power Requirements
Item
Xerox Nuvera
Digital Production System
Size – Printer w/ 1 SFM
132" (W) X 29 " (D) X 61.6 " (H)
/ Scanner & MFF
3353 mm x 737 mm x 1565 mm
Size – Printer w/ 1 SFM
125" (W) X 29 " (D) X 61.6 " (H)
& SEM / FTM
3175 mm x 737 mm x 1565 mm
Size – Printer w/ 1 SFM
124" (W) X 29 " (D) X 61.6 " (H)
& SEM / BFM
3150 mm x 737 mm x 1565 mm
Width of additional
31.7", 805mm
SFM
Width of BFM Plus
49", 1233mm
Service Space
Fixed: 163" (W) x 112" (D)
(MFF Config.)
Moveable: 163" (W) x 92" (D)
Service Space
BFM: 145" (W) x 112" (D)
(BFM / FTM Config.
with SEM)
FTM: 143" (W) x 112" (D)
Weight
1,753 lb. (795.2 kg)
(MFF Config. w/
Additional SFM – 423 lbs. (192 kg)
scanner)
Weight
BFM: 1763 lb. (800 kg)
(BFM / FTM Config.
FTM: 1713 lb. (777 kg)
with SEM)
Additional SFM – 423 lbs. (192 kg)
Power Requirements
187 – 240 Volts AC (Nominal), 50 Amp ,
North America / Japan
50/60 Hz wall service
(MFF / BFM Finishing)
Note – FTM and DFA finishers will require
additional power
Power Requirements
187 – 240 Volts AC (Nominal), 30 Amp +
Europe / FX-IBG
20 Amp (2) , 50/60 Hz wall service
Feeders and Finisher modules (BFMs) will
need additional 187 – 240 VAC (Nominal),
20 Amp, 50/60 Hz wall service
Note – FTM and DFA finishers will require
additional power
* - Please refer to supported inline DFA finishing devices Solution Planning Guides for Product Space and
Power Requirements.
** - the following configuration is not Energy Star compliant:
100 ppm printer-only configuration with a BFM
®
100/120/144 EA
( 4140mm x 2839mm)
( 4140mm x 2336.8mm)
3683mm x 2839 mm
3632mm x 2839 mm
Comments
Printer Digital Tower 61.6" (1565 mm) (Height)
DFA finishing devices vary by device*.
Optional
Optional, BFM Plus and Interface Module used with BFM (with top
tray) in dual BFM installations.
- Fixed (stationary) installation: rear of the system should be at least
30" from the wall, machine, or rear obstruction..
- Moveable installation: rear of the system should be at least 10" from
the wall and must be on mobility plates OR hard surface floor AND
with no more than 4 modules including MFF and MFF Interface
Module.
At least 30" from the wall in rear.
DFA finishing will increase width - FTM config. dimensions do not
include DFA Finisher(s) dimensions or service space.
With consumables loaded, except media
With consumables loaded, except media
FTM config. listing does not include DFA Finisher(s) weight.
• UL & cUL compliant
• Complies with the FEMP (Federal Energy Management Program)
via the machine circuit breaker (CB); with the CB switched off, the
system consumes less than 1 watt.
• Energy Star (eStar) compliant**
• Environmental Choice (Canada)**
Complies with Section 508 of the ADA Rehabilitation Act
• Units are compliant with applicable EU directives and are CE
marked
- 14 -