Siemens SITRANS F Series Operating Instructions Manual page 158

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

Parameter lists
F.8 800-899
Param‐
Meter
Display
eter ID
version
view
823
Advanced
-
824
Advanced
-
825
Advanced
-
826
Advanced
-
830
Advanced
R8
831
Advanced
R9
832
Advanced
R9
833
Advanced
R10
834
Advanced
R10
840
Advanced
841
Advanced
R7
842
Advanced
-
843
Advanced
R1
844
Advanced
R1
845
Advanced
R1
846
Advanced
R2
847
Advanced
R2
848
Advanced
R2
849
Advanced
R3
850
Advanced
R3
851
Advanced
R3
852
Advanced
R4
853
Advanced
R4
854
Advanced
R4
855
Advanced
R5
856
Advanced
R5
857
Advanced
R5
858
Advanced
R6
158
Parameter/data type
Lowest measured leak‐
age value
Date of lowest leakage
value
Highest measured leak‐
age value
Date of highest leakage
value
Next settling date
Latest settling date
Latest totalizer 1 value
Previous settling date
Previous totalizer 1 value
Tariff control mode
Date of tariff reset
Reset tariff values
Tariff1 volume 1
Tariff1 period time end
Tariff1 upper limit range
Tariff2 volume 2
Tariff2 period time end
Tariff2 upper limit range
Tariff3 volume 3
Tarif3 period time end
Tariff3 upper limit range
Tariff4 volume 4
Tariff4 period time end
Tariff4 upper limit range
Tariff5 volume 5
Tariff5 period time end
Tariff5 upper limit range
Tariff6 volume 6
Factory settings
Fixed parameter or meter data that are not changeable
1 000 000 000
2000-01-01 T00:00
-1x10
9
2000-01-01 T00:00
PS3 production date and
time
PS3 production date and
time
0
PS3 production date and
time
0
Off
PS3 production date and
time
No
0
360 min = 6:00 [24:00]
15%
0
540 min = 9:00 [24:00]
30%
0
720 min = 12:00 [24:00]
45%
0
1080min=18:00 [24:00]
60%
0
1260 min = 21:00 [24:00]
80%
0
Operating Instructions, 03/2020, A5E03071515-AH
Data range
The unit is updated once param‐
eter 811 change is downloaded
to device and afterwards uploa‐
ded to pc
year-month-day T hours:mi‐
nutes:seconds
The unit is updated once param‐
eter 811 change is downloaded
to device and afterwards uploa‐
ded to pc
year-month-day T hours:mi‐
nutes:seconds
year-month-day T 23:59:59
year-month-day T 23:59:59
year-month-day T hours:mi‐
nutes:seconds
Off / time / range / combination
year-month-day T hours:mi‐
nutes:seconds
Yes / No
Value is reset to "No" when up‐
loading device parameters to pc
after command execution
0 to 1439 minutes (23:59)
0 to 100% Qn (Q3)
0 to 1439 minutes (23:59)
0 to 100% Qn (Q3)
0 to 1439 minutes (23:59)
0 to 100% Qn (Q3)
0 to 1439 minutes (23:59)
0 to 100% Qn (Q3)
0 to 1439 minutes (23:59)
0 to 100% Qn (Q3)
SITRANS FM MAG 8000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents