Siemens SITRANS F Series Operating Instructions Manual page 113

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

MAG 8000 (7ME8610) and MAG 8000 (7ME6820)
Dimensions Inches
Size
ANSI Class 150
1"
1 ½"
2"
2 ½"
3"
4"
5"
6"
8"
10"
12"
14"
16"
18"
20"
24"
External battery pack and cable
Note
Physical orientation of battery pack may influence battery capacity.
Optimal battery capacity is achieved with battery pack in an upright position as shown.
The cable for the battery pack connection must be ordered separately.
For information about battery disposal, see Battery disposal (Page 85).
SITRANS FM MAG 8000
Operating Instructions, 03/2020, A5E03071515-AH
D
PCD
4.25
3.12
5
3.88
6
4.75
7
5.5
7.5
6
9
7.5
10
8.5
11
9.5
13.5
11.75
16
14.25
19
17
21
18.75
23.5
21.25
25
22.75
27.5
25
32
29.5
T
B
0.56
0.62
0.68
0.62
0.75
0.75
0.88
0.75
0.94
0.75
0.94
0.75
0.94
0.88
1
0.88
1.12
0.88
1.19
1.00
1.25
1.00
1.38
1.12
1.44
1.12
1.56
1.25
1.69
1.25
1.88
1.38
Technical data
10.12 Dimension drawings
Bolting
Holes
Bolts
4
9/16"
4
9/16"
4
5/8"
4
5/8"
4
5/8"
8
5/8"
8
3/4"
8
3/4"
8
3/4"
12
7/8"
12
7/8"
12
1"
16
1"
16
1 1/8"
20
1 1/8"
20
1 1/4"
113

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents