A Program - Fetco CBS-1221 Users Manual And Operator Instructions

Single air pot brewer
Table of Contents

Advertisement

A PROGRAM

The settings below are shown for the top batch on a single brewer top left button on a twin brewer.
See how to access all A menus on the previous page. Below are the brew settings for default A1 & A2 batches
POSITION
Program Items
A11
Batch Volume
Brew Time
A12
(MIN:SEC)
A13
Prewet Perc.
Prewet Delay
A14
(Pause after prewet
completes)
A16
Drip Delay
Batch Enabled
A20
A20 YES -
NO +
A21
Batch Volume
Brew Time
A22
(MIN:SEC)
A23
Prewet Perc.
Prewet Delay
A24
(Brew pause after
prewet completes)
A26
Drip Delay
Batch Enabled
A30
A30 YES -
NO +
A31
Batch Volume
A32
Brew Time
A33
Prewet Perc.
Prewet Delay
A34
(Brew pause after prewet
completes)
A36
Drip Delay
A70
Copy From Batch
Batch Copy
A72
Copy To Batch?
(PASTE TO)
A11 Single Topmost Batch cannot be disabled. A21 & A31 middle and bottom batches may be disabled.
† DRIP DELAY will not activate when STOP is pressed within 5 seconds of starting a brew time
.
Go to fetco.com for the latest versions of all information
Factory set Default Programming Range Increments
2.20liters
0.58gal
4:00 minutes
0%
0% [1:00 Min]
2:00 mm:ss
YES
(Active)
2.20liters
0.58gal
4:00 minutes
0%
0% [1:00 Min]
2:00 mm:ss
YES
(Active)
2.20liters
0.58gal
4:00 minutes
(MIN:SEC)
0%
0% [1:00 Min]
2:00 mm:ss
A71
A72
Menu Features: Batch Parameters
0.95 to 3.25L
0.25 to 0.85 gal
2:00 – 12:00
0.00 – 25.0%
[0:10 – 5:00]
0:30 – 6:00 min.
Middle and Bottom
batches A2,A3
0.95 to 3.25L
0.25 to 0.85 gal
2:00 – 12:00
0.00 – 25.0%
[0:10 – 5:00]
0:30 – 6:00 min.
Middle and Bottom
batches A2,A3
0.95 to 3.25L
0.25 to 0.85 gal
2:00 – 12:00
0.00 – 25.0%
[0:10 – 5:00]
0:30 – 6:00 min.
A71 1 (1-6)
A72.1 (1-6)
User Guide & Operator instructions
Page 5
Notes
0.05L
Unit software is in liters;
0.01G
Can convert to gallon
Default total brew time is
15 sec
6:00 minutes
Percentage of total brew
1%
volume
The time between
prewetting and start of
10 sec
brew cycle.
This feature appears
ONLY if Prewet >0:00
Time brew basket should
remain in place during final
drip-out
10 sec
Drip delay remains "ON"
for 2:00 minutes if STOP is
pressed during brew
Batches may be
Batch on
individually enabled,
or off
rewritten or deactivated
0.05L
Unit software is in liters;
0.01G
converts to gallon
Default total brew time is
15 sec
6:00 minutes
Percentage of total brew
1%
volume
10 sec
See Note A14
10 sec
See Note A16
Batches may be
Batch on
individually enabled,
or off
rewritten or deactivated
0.05L
Unit software is in liters;
0.01G
converts to gallon
Default total brew time is
15 sec
6:00 minutes
Percentage of total brew
1%
volume
10 sec
See Note A14
10 sec
See Note A16
P194Re0
November 2020