Error Codes; Operator Training - Fetco CBS-1221 Users Manual And Operator Instructions

Single air pot brewer
Table of Contents

Advertisement

ERROR CODES

DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND/OR CORRECTED
Contact specialized personnel for error codes
Code
Description
Software error-error on start up or
001
corrupted software
050
Short-circuit in temperature probe
051
Open temperature probe.
Initial Fill Error.
100
Initial fill time took longer than
expected after power up.
Error on refill-.
101
Tank did not refill within expected
time.
Heater open, high limit thermostat,
201
or Solid State Relay (SSR) fault
255
Touch pad error
NO
BSKT
Insert Brew Basket
Review the operating procedures with whoever will be using the brewer.
Pay particular attention to the following areas:
1. Always pre-heat the dispensers before the first use of each day by filling them half way with hot water, and letting
them stand for at least 5 minutes.
2. Do not remove the brew basket from a coffee brewer until it has stopped dripping.
3. Make sure the dispenser is empty before brewing into it.
4. Show how to attach covers, close, and or secure the dispensers for transporting.
5. Show the location and operation of the water shut off valve as well as the circuit breaker for the brewer.
6. Steam from the tank will form condensation in the vent tubes. This condensation will drip into and then out of the
brew baskets. Up to 1/4 cup/118cc discharging overnight is possible. Place an appropriate container under each
brew basket when not in use.
7. We recommend leaving the power to the brewer on overnight. The water tank is well insulated and very little
electricity is used to keep the tank hot. Leaving the brewer in the "ON" position will also avoid delays at the beginning
of shifts for the brewer to reach operating temperature.
Go to fetco.com for the latest versions of all information
Possible Cause
Improper start-up or
shutdown
Probe failure.
Bad probe connection, or
probe failure.
Water supply flow rate is
too low.
Water supply flow rate is
too low.
Failure of heating element,
SSR, high limit or low
voltage
Usually from longer than 2
min contact. Or faulty
reassembly after service
Brew basket must be in
place
This is a
SAFETY FEATURE

Operator Training

User Guide & Operator instructions
Page 9
Corrective Action
Restart , if still fault: reload software
Replace probe.
Check all connections. Replace probe
if necessary.
Watch for short potting during brew
cycle. Investigate cause of low flow
rate. (Clogged water filter...)
Watch for short potting during brew
cycle. Investigate cause of low flow
rate. (Clogged water filter...)
Check and replace heating elements,
SSRs, high limit devices if necessary.
Restart , if still fault: reload software.
If mechanical: replace module
Insert brew basket into brewer rails to
enable brewer
P194Re0
November 2020

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents