Error Message; Service Call - Roland SOLJET Pro III XC-540 Service Notes

Hide thumbs Also See for SOLJET Pro III XC-540:
Table of Contents

Advertisement

6-17 ERROR MESSAGE

NO
CHECKING POINT
1

service call

2
Internal Error
6-18 SERVICE CALL
CODE
CONTENTS
Disorder of
communication with Sub
CPU
0002
This occurs when the Sub
CPU is not detected after
turning on the machine
0004 SRAM error
Revised 3
An error occurs during
0005
downloading a program for
sub CPU.
Revised 3
An error occurs when start
0006
connecting to sub CPU.
Revised 3
An error occurs during
0007
sending a command.
Revised 3
There is a problem with
synchronizing serial
0008
communication to Sub
CPU.
Network I/F Initialize has
0010
not been done.
Limit Position Initialize has
0101
not been done.
Even though the machine
Revised 3
carries out the regular
movement, the output of
0102
Head Lock Sensor does
not reach the expected
value.
ACTION
REFERENCE
Refer to service call
Restart the machine
Upgrade the firmware to
the latest version
CAUSE
Sub Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
SRAM has broken.
Sub Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
A noise on a signal.
A noise on a signal during sending a
command.
Sub CPU was reset to default.
Get into communicate when Sub CPU was
reset to default.
Sub Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
A noise on a signal during sending a
command.
Sub CPU was reset during sending a
command.
Sub Board does not work correctly.
Sub CPU does not work correctly.
There is a bad connection between Main
Board and Servo Board.
A noise on a signal.
Network I/F does not work correctly.
Firmware for Network I/F is not installed.
Limit Position Initialize has not been done
correctly.
Head Lock Sensor does not work correctly or
is broken.
Refer to service call
This message is displayed when an unexpected error occurs. Restart
the machine and see if the same error occurs again.
Check the revision record of the firmware version and upgrade it if the
error has been solved in the firmware.
Check Cable connection between CN8 of Main Board and CN11 of
Servo Board.
Check Cable connection between CN7 of Main Board and CN4 of
Heater Board.
Check the other Cable connections of Servo Board
Heater Board replacement
Servo Board replacement
Main Board replacement
Flexible Cable replacement
Servo Board replacement
Check Cable connection between CN8 of Main Board and CN11 of
Servo Board.
Check Cable connection between CN7 of Main Board and CN4 of
Heater Board.
Check the other Cable connections of Servo Board
Heater Board replacement
Servo Board replacement
Main Board replacement
Flexible Cable replacement
Check Cable connection between CN8 of Main Board and CN11 of
Servo Board.
Check Cable connection between CN7 of Main Board and CN4 of
Heater Board.
Check the other Cable connections of Servo Board
Heater Board replacement
Servo Board replacement
Main Board replacement
Flexible Cable replacement
Check Cable connection between CN8 of Main Board and CN11 of
Servo Board.
Check Cable connection between CN7 of Main Board and CN4 of
Heater Board.
Check the other Cable connections of Servo Board
Heater Board replacement
Servo Board replacement
Main Board replacement
Flexible Cable replacement
Check Cable connection between CN8 of Main Board and CN11 of
Servo Board.
Check the other Cable connections of Servo Board
Servo Board replacement
Main Board replacement
Flexible Cable replacement
Main Board replacement
Check the firmware is installed into Network I/F
Carry out Limit Position Initialize
Head Lock Sensor replacement
Check the backlash or loose with the driving parts of the carriage.
6-10
OUTLINE
ACTION

Hide quick links: