4-7 LINEAR ENCODER SETUP (Referential Time : 10min.)
LINEAR ENCODER SETUP is performed to confirm that the installation of Linear Encoder is proper, and also
to confirm that it properly reads and corrects the width of the scale, which is stretched or shrunk due to the
operation environment, by the software coordinates. This operation is required when Limit Sensor, Encoder
Scale or Encoder Module is replaced or the position is adjusted.
Turn on the SUB POWER SW while pressing [
1
and [
] keys to enter the SERVICE MODE.
Lower the Pinch Rollers.
2
Make sure to unload the media when it is set on the
machine.
Also, the media clamps must be removed.
Select the [LINEAR ENCODER] menu in the SERVICE
3
MENU and press the [ENTER] key.
], [
]
[
] , [
] , [
MENU
SERVICE MENU
SERVICE MENU
PRINT MENU
PRINT MENU
LINEAR ENCODER
NOW PROCESSING..
POS:
4-42
] + SUB POWER ON
[MENU] key
[ ] [ ]
[ ]
1361.00mm