Valve Drain Requirements
10
Use the flexible drain hose, that is included, measure and cut to the length needed. Flexible drain hose
is not allowed in all localities (check your plumbing codes). If local codes do not allow use of a flexible
drain hose, a rigid valve drain run must be used. Buy a compression fitting (1/4 NPT x 1/2 in. minimum
tube) and 1/2" tubing from your local hardware store. Then plumb a rigid drain as needed (see Figure
3).
NOTE:
Avoid long drain hose runs, or elevating the hose more than 8' above the floor. Make the
water softener valve drain as short and direct as possible.
Clip
Cut barbs from valve drain elbow (pull clip
and remove drain valve elbow from valve)
Figure 3
1/4" NPT thread
Compression fitting 1/4 NPT x
barbs
1/2" O.D. tube (not provided)
1/4" NPT thread
Barbs for 3/8" I.D. tubing
Hose clamp
Drain hose
1/2" outside diameter copper
tube (not provided)