Differential Connections for Grounded Signal Sources

Figure 3-3 shows how to connect a ground-referenced signal source to a
NI PCI-1200 configured for DIFF input mode. Configuration instructions
are in the
Analog I/O Configuration
Configuring the NI
1
ACH0
3
ACH2
5
ACH4
+
7
ACH6
2
ACH1
4
ACH3
+
6
ACH5
8
ACH7
11
AGND
NI PCI-1200 in DIFF Configuration
Figure 3-3. Differential Input Connections for Grounded Signal Sources
With this connection type, the instrumentation amplifier rejects both the
common-mode noise in the signal and the ground-potential difference
between the signal source and the NI PCI-1200 ground (shown as V
Figure 3-3).
section of Chapter 2,
PCI-1200.