GENERAL INFORMATION
GENERAL INFORMATION

5 SYSTEM LAYOUT

P
M

6 TECHNICAL SPECIFICATIONS

DESCRIPTION
Type of storage cylinder
Heat exchanger layout
Storage cylinder capacity
Useful non-solar volume (Vbu) (*)
Solar usable volume (Vsol) (**)
Diameter of storage cylinder with insulation
Diameter of storage cylinder without insulation
Height with insulation
Height without insulation
Insulation thickness
Total net weight
First magnesium anode (Ø x length)
Second magnesium anode (Ø x length)
Flange diameter (external/internal)
Diameter/length of sensor sockets
Sleeve for electric heating element (***)
Maximum operating pressure of storage cylinder
Maximum operating temperature
Discharges according to EN 12897:2006 ∆T=45 °C (am-
bient 20°C and storage at 65°C)
Energy class
Insulation type
Vbu (*) The non-solar usable volume indicates the quantity of water (in litres) heated directly by the thermal integration coil. It
is calculated as the volume between the upper part of the heater and the lower part of the thermal integration element
(integration coil lower turn). The value shown in the tale refers to the coil located in the central part of the puffer. The
position of the coil can be changed and the volume changes as a result.
Vsol (**) The usable solar volume indicates the quantity of water (in litres) heated directly by the solar coil (placed in the lower
part of the heater) minus the non-solar volume (Vbu).
(***)
Electrical heating element (not supplied).
UAC
1
2
3
4
3
4
2
3
EAF
SB
1
Storage cylinder
2
Probe/electronic anode pit (optional)
3
Flange for inspection/insertion of additional exchang-
7
ers
6
4
Probe pit
5
Thermometer connection
5
6
Insulation
7
Cover
M
Guide
UAC
Domestic hot water outlet
EAF
Domestic cold water inlet
P
Socket
SB
Storage cylinder drain
7200/3F HV PLUS
800
1000
Vertical, glazed
Horizontal
749
955
420
490
329
465
990
990
790
790
1875
2205
1810
2140
150
190
32x700
-
32x400
290/220
10
130
142
3,12
3,408
C
C
Soft PU shells
4
1500
2000
3000
1430
1990
2959
790
1210
1745
640
780
1214
1200
1300
1450
1000
1100
1250
2185
2470
2680
2120
2425
2650
100
305
325
543
32x700
8/200
1" 1/2
8
99
162
186
344
3,888
4,464
8,26
C
C
l
l
l
mm
mm
mm
mm
mm
kg
mm
mm
mm
mm
Ø
bar
°C
W
kWh/24h
-