System Schematic; Preliminary Checks; Installation And Putting Into Service - Riello SC ACS 80 Manual

Table of Contents

Advertisement

Example of wall mounted installation
b
In case of recirculation, provide a suitably sized expansion tank in order to avoid overpressure due to thermal ex-
pansion and water hammer.

PRELIMINARY CHECKS

Carefully remove the packing and check that the product is complete and undamaged. If any defect or damage is de-
tected, do not install or attempt to repair the product but return it to the retailer. Dispose of packaging in compliance with
applicable law.
b
Make sure that the installation position provides easy visibility of and access to the safety valves.
b
Connect the safety valves to a drain in conformity to applicable standards.
b
Install the product as near as practical to the storage cylinder. The product is designed to work with a pipe length
of 4 metres (inlet and return) between itself and the storage cylinder. Get the storage cylinder away can result in
performance drops in terms of potential and reactivity.
b
Disconnect the product from the mains power supply before commencing any work on it.
b
The product must be installed in conformity to the laws and standards applicable in the country of installation.
b
The manufacturer's responsibility ends with the supply of the product. The product must be installed in conformity
to applicable standards by suitably qualified persons employed by a company that assumes full responsibility for
the completed installation.

INSTALLATION AND PUTTING INTO SERVICE

Bear in mind the following before installing the product:
- The product is designed to mix domestic hot water from a storage cylinder. Any other use, or any use incompatible with
the product's technical specifications, is considered improper. Do not connect the product directly to a boiler.
- The product is not designed to be operated by children or persons with limited physical, psychological, sensorial or
mental capacities.
- If the piping needed to connect the product to the water system is damaged, it must be replaced by a suitably qualified
person.
- The installation must comply with all applicable laws and standards.

SYSTEM SCHEMATIC

Primary inlet
Primary outlet (return)
INSTALLATION
8
Cold water inlet
DHW outlet
Recirculation