CLI Commands

frame-relay lmi-n393dte

Use the frame-relay lmi-n393dte command to set the number of status polling intervals
over which the error threshold is counted (the monitored event count). To set the error
threshold, refer to
number of events the station receives error_threshold number of errors, the interface is
marked as down.
Use the no form of this command to revert to the default value.
Syntax
[no] frame-relay lmi-n393dte events
Parameters
Parameter
events
User level
read-write
Context
Interface: Serial (DS1 FR L2, USP FR L2)
Example
To set the number of events over which the error threshold is calculated to 5:
G350-001(if:Serial 2/1:1)# frame-relay lmi-n393dte 5
Related commands
encapsulation,
frame-relay
lmi-type,
198 Avaya G250 and Avaya G350 CLI Reference
frame-relay lmi-n392dte
Description
The number of events
frame-relay
interface-dlci,
frame-relay
priority-dlci-group,
on page 197. In other words, if within events
frame-relay
lmi-n391dte,
frame-relay
Possible
Default
Values
Value
1-10
4
frame-relay
lmi-n392dte,
traffic-shaping,
ip address