Delime Instructions - Jackson RackStar Series Installation, Operation & Service Manual

Conveyor dischmachines
Table of Contents

Advertisement

OPERATION
DISPLAY
INSTRUCTIONS
DELIME
INSTRUCTIONS
!
WARNING
WARNING! Deliming
solution can cause
chemical burns. Follow
instructions provided
with deliming solution.
This equipment is not
recommended for use
with deionized water or
other aggressive fluids.
Use of deionized water or
other aggressive fluids
will result in corrosion
and failure of materials
and components. Use of
deionized water or other
aggressive fluids will
void the manufacturer's
warranty.
07610-004-33-05-E
Operational Messages
DISPLAY
CONDITION
One of the doors is not fully closed or one of the switches is not being
"Check doors"
triggered.
"Filling"
The wash tank is filling with water.
"Heating"
The machine is heating the water in the wash tank.
"Delime"
The Delime Button has been pressed.
"Ready"
The machine is ready for operation.
"Wash Temp"
A rack of dishes is progressing through the wash section.
Alternates "Wash Temp"
A rack of dishes is progressing through the rinse section.
& "Rinse Temp"
Consult chemical supplier's instructions before deliming the machine.
1. Disconnect or turn-off chemical feeder pumps.
2. Turn machine power off and drain the machine.
3. Make sure the machine is clean and all parts are in place.
4. Ensure doors are closed and then press Power Button to begin the filling
process.
5. Fill machine with the correct amount of delime solution as recommended by
the chemical supplier.
6. The wash tank holds 25 gallons and pre-wash tank holds 15.8 gallons of
water.
After chemicals are added:
7. Make sure doors are closed.
8. Press Delime Button and run machine the length of time recommended by
chemical supplier.
9. Press Delime Button again to stop the deliming process.
10. Press Power Button to shut the machine off.
11. Wait five minutes, open the doors and inspect inside of the machine. If the
machine is not delimed, drain and re-fill the machine, then repeat steps
5–10.
12. When deliming is complete, drain and re-fill the machine. Then run the
machine two cycles to remove residual deliming solution.
13. Drain and re-fill the machine.
14. Re-connect chemical feeder pumps.
15. The machine is ready to use.
OPERATING INSTRUCTIONS
30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents