Motor Modules Chassis-2

7.5 Installation

7.5
Installation
The Motor Module Chassis-2 is secured using two M10 bolts on the top of the device, which
are screwed onto the rear mounting panel of the control cabinet.
Then the Motor Module Chassis-2 is fastened to the mounting surface of the control cabinet
using a mounting bracket.
Mounting dimensions in the control cabinet
Refer to the following diagrams for the mounting dimensions when installing a Motor Module
Chassis-2 in a control cabinet.
Front view of the control cabinet
Side panel of the control cabinet
Mounting surface for the Motor Module
306
Frame size FS2
Frame size FS4:
Air-cooled chassis power units