Article No. of the Motor
Table 9- 5
Article No. of the Motor
Module Chassis-2
Air-cooled chassis power units
Manual, 07/2019, 6SL3097-4AE00-0BP9
Type
Module
rating
6SL3320-...
[kW]
1TG28-5AA3
75
1TG31-0AA3
90
1TG31-2AA3
110
1TG31-5AA3
132
1TG31-8AA3
160
1TG32-2AA3
200
1TG32-6AA3
250
1TG33-3AA3
315
1TG34-1AA3
400
1TG34-7AA3
450
1TG35-8AA3
560
1TG37-4AA3
710
1TG38-1AA3
800
1TG38-8AA3
900
1TG41-0AA3
1000
1TG41-3AA3
1200
Maximum pulse frequency when using a motor reactor with devices with a rated pulse
frequency of 2.5 kHz
Type
rating
6SL3321-...
[kW]
1TE36-6AA0
315
1TE37-4AA0
355
1TE41-0AA0
500
1TE41-1AA0
560
1TE41-2AA0
630
Output current for a
pulse frequency of 1.25
kHz [A]
Line voltage 3 AC 500 ... 690 V
85
100
120
150
175
215
260
330
410
465
575
735
810
910
1025
1270
Output current for a
pulse frequency of 2.5 kHz
[A]
Line voltage 3 AC 380 ... 480 V
655
740
975
1075
1200
Motor-side power components
9.2 Motor reactors
Maximum pulse frequency when
using a motor reactor
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
Maximum pulse frequency when
using a motor reactor
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
2.5 kHz
357