Final Check Out - Slant/Fin Q3-4 Supplemental Instructions

High efficiency oil-fired hot water boiler
Table of Contents

Advertisement

Available languages

Available languages

Final Check Out:

• Carefully examine complete vent system for leaks. This
may be done by spraying soapy solution on all joints
and watching for bubbles during pre-purge. The hot vent
can be checked with lit taper for signs of air movement
around joints or seams.
• Insure all safety devices and electrical components
have been set for normal operation. Insure all electrical
connections are tight and wiring is secure.
• Insure homeowner is informed and understands the
following:
1.
Where circuit breaker or fuse is located in main
electrical panel.
2.
Where Boiler switch is located, and switch "on" and
"off" positions if not obvious.
3.
Where oil shut-off valve from oil storage tank is
located.
4.
To keep area around vent terminal free of snow, ice,
and debris.
5.
How to operate the thermostat, and other related
accessories.
6.
How to operate manual reset button on primary
control, and especially when not to push the reset
button.
7.
How and where to visually inspect the venting system
for leaks or other problems.
8.
How to inspect, clean and replace the air filter, and
other homeowner maintenance procedures.
9.
Who to call for emergency service and routine annual
service.
10.
Terms and conditions of the manufacturer's warranty
and the contractor's warranty.
FINAL CHECK OUT
9
P/N 473921000