Siemens SITRANS TH100 Operating Instructions Manual page 194

Temperature transmitter with 4to 20 ma/hart
Table of Contents

Advertisement

Technical data
12.1 SITRANS TH100
Output
Effect of load impedance
Long-term drift
Note
Measurement errors
Greater measuring errors may occur if the transmitter is installed on a DIN rail in an environment
with severe interference. Observe the applicable ESD directives.
Operating conditions
Ambient temperature
Storage temperature
Relative humidity
Electromagnetic compatibility
Errors with EMC influences
Table 12-1
Mechanical construction
Core cross-section
Weight
Dimensions
Material
Degree of protection
Factory setting Pt100 (DIN IEC)
Measuring range
Fault current
194
ESD in accordance with
EN 61000-4-2
HF radiation according to
EN 61000-4-3
Burst in accordance with
EN 61000-4-4
HF energizing according to
EN 61000-4-6
Housing
Terminals
< 0.025% of max. span / 100 Ω
< 0.025% of max. span in the first month
< 0.035% of max. span after one year
< 0.05% of the max. span after 5 years
-40 ... +85 °C (-40 ... +185 °F)
-40 ... +85 °C (-40 ... +185 °F)
≤ 98%, condensing
As per EN 61326 and NAMUR NE21
< 0.10% of measuring span
< 0.8% of measuring range 0 ... 100 °C
< 0.1% of measuring range 0 ... 100 °C
< 0.9% of measuring range 0 ... 100 °C
Max. 2.5 mm
(AWG 13)
2
50 g
See SITRANS TH100 dimension drawings (Page 217)
Molded plastic
In accordance with IEC 60529
IP40
IP00
In three-wire input
0 ... +100 °C (32 ... +212 °F)
22.8 mA
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART