VHU INSULATED HUMIDIFIED CABINETS - REMOVAL AND REPLACEMENT OF PARTS

DOOR GASKET

1.
Open door to access gasket.
2.
Remove door gasket by pulling it out from
retaining channel in door assembly.
Fig. 24
3.
Install gasket in each corner on door assembly.
A.
Press gasket retaining lip into channel on
door assembly.
B.
Work gasket into channel about four inches
away from corner, in each direction.
Fig. 25
4.
Starting at the top, press gasket retaining lip into
channel on door assembly while moving toward
middle.
5.
Repeat each side to complete gasket installation.
6.
Check door for proper operation.

DOOR LATCH (MAGNETIC)

1.
Open door.
2.
Remove screws securing door latch to door
assembly.
3.
Reverse procedure to install.
4.
Check for proper operation.
1.
Unscrew fuse cover from back panel.
Page 11 of 16
Fig. 26

FUSE

Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.