QPC414 Network Card
Application
Option A: In-house remote peripheral equipment
(RPE), microwave, fiber optics
Option B: T-1 facilities (including PRI/DTI),*
channel service unit
To connect 1.5M RPE to T-1 through channel service unit, select option B. For 2M RPE, jumper plugs are
*
not used.
Note 1: Possible jumper locations for vintage B (for different styles/series):
J3—E11 or H11
J4—H17 or E7
S1 and S2—E33
Note 2: Possible jumper locations for vintage A (for different styles/series). These cards do not have the
option selection and can only be used in the option A setting:
J3—H5 or E11
J4—H17 or E7
S1 and S2—E33
Note 3: Connectors and loop relations:
Even loop: J1 faceplate connector, jumper at J4 or S1
Odd loop: J2 faceplate connector, jumper at J3 or S2
Option settings
Pin connection
J3/S2 and J4/S1
connect pins 2 and 3
(pin 1 is next to the white dot)
connect pins 1 and 2
(pin 1 is next to the white dot)