Acceptance tests
553-3001-211 Standard 17.00 April 2000
5
Test an automatically identified outward dialing (AIOD) trunk card:
LD 41
AIOD l s cloop, shelf, and card numbers
If the system response is other than OK, see the X11 Administration
(553-3001-311) to analyze the messages.
6
End the session in LD 41:
****
Procedure 10
Tone and digit switch cards
Use this procedure to test a tone and digit switch (TDS) card or to test the TDS
function of an NT8D17 Conference/TDS Card.
1
Log into the system:
LOGI (password)
2
Obtain a list of terminal numbers (TNs) for disabled TDS cards:
LD 34
STAD
3
If the TDS loop to be tested is disabled, enable it.
For an NT8D17 Conference/TDS Card, enter:
ENLX loop
(the TDS/MFS loop is the even loop of the conference/TDS loop pair)
Note: The conference/TDS card is not enabled automatically when it
is inserted. You must enable the card with the command ENLX. (This
command is used in LD 34 and LD 46 to address even loops and in
LD 38 to address odd loops.) Enabling the loops with the command
ENLL does not enable the hardware for the card.
For other than an NT8D17 Conference/TDS Card, enter:
ENLL loop
4
Test the TDS loop:
TDS loop
If the system response is other than OK, see the X11 Administration
(553-3001-311) to analyze the messages.
5
End the session in LD 34:
****