Nortel Meridian 1 Installation Manual page 58

Circuit card installation and testing
Table of Contents

Advertisement

Page 58 of 74
Option settings
QPC43 Peripheral Signaling Card
NT5D21 Core/Network Module
NT8D35 Network Module
QPC71 E&M/DX Signaling and Paging Trunk Cards
Application
1
E&M
off
Paging
off
DX 2-wire
on
(conductor
loop <
2.5 K ¾)
DX 2-wire
on
(conductor
loop >
2.5 K ¾)
DX 4-wire
off
(conductor
loop <
2.5 K ¾)
DX 4-wire
off
(conductor
loop >
2.5 K ¾)
Note: DX trunks must be balanced correctly. If the loop is <2.5 K ¾, far-end balancing is standard. If the
loop is >2.5 K ¾, far end balancing requires standard plus 2.5 K ¾. To connect PBX to PBX, switches should
be arranged for loops to be >2.5 K ¾ at one end and <2.5 K ¾ at the other. Apply similar treatment when
connecting to Pulse QPJ69 trunks.
553-3001-211 Standard 17.00 April 2000
Options (minimum vintage N)
Unit 0 E35 switch
2
3
4
5
off
off
on
off
off
off
off
off
on
off
off
off
on
on
on
off
off
off
off
on
off
on
on
on
6
7
8
1
off
on
off
off
off
off
off
off
on
off
on
on
on
off
on
on
on
off
on
off
on
off
on
off
Plug location
Unit 1 E5 switch
2
3
4
5
off
off
on
off
off
off
off
off
on
off
off
off
on
on
on
off
off
off
off
on
off
on
on
on
F13
6
7
8
off
on
off
off
off
off
on
off
on
on
off
on
on
off
on
on
off
on

Advertisement