Installing the Cisco NCS 4216
DETAILED STEPS
Step 1
Choose a slot for the module. Make sure that there is enough clearance to accommodate any equipment that will be
connected to the ports on the module. If a blank module filler plate is installed in the slot in which you plan to install the
module, remove the plate by removing its 2 Phillips pan-head screws.
Step 2
Fully open both the ejector levers on the new module, as shown in the figure below.
Caution
To prevent ESD damage, handle modules by carrier edges only.
Step 3
Position the module in the slot. Make sure that you align the sides of the module with the guides on each side of the slot,
as shown in the figure below.
Figure 12: Cisco NCS 4216 RSP Installation
Step 4
Carefully slide the module into the slot until the EMI gasket on the module makes contact with the module in the adjacent
slot and both the ejector levers have closed to approximately 45 degrees with respect to the module faceplate.
If the top slot already has an RSP module installed, and you install a second RSP module in the slot below
Caution
it, be careful not to damage the EMI gasket of the bottom RSP module against the ejector levers of the top
RSP during insertion.
Installing an RSP Module
Cisco NCS 4216 Hardware Installation Guide