2.1 Environment

The PD drive operates in an ambient temperature range of 0°C (32°F) to 50°C (122°F)
ambient air temperature for all models.
Environment
Items
Requirements
Ambient
0∼50[℃]
Temperature
Surrounding
90[%]RH or
Humidity
Vibration
External
Acceleration
Vibration
4.9[㎨] or below
No exposure to direct sunlight
Environmental
No corrosive/flammable gas
Requirements
No oil or dust
In case of a closed space, adequate ventilation

Table 2. Drive Installation Environment

Parker Hannifin
Caution
Please attach the cooling fan to the control panel, so
that the temperature does not exceed the workable
temperature.
Caution
Freezing or condensation inside the drive due to long-
term non-use may damage the drive. When operating
below
after non-use, please remove water before operating.
Excessive vibration may shorten the life cycle of the
bearings