Use Of Elbows - Heat & Glo COSMO32-IFT-B Installation Manual

Table of Contents

Advertisement

D. Use of Elbows
Diagonal runs have both vertical and horizontal vent as-
pects when calculating the eff ects. Use the rise for the
vertical aspect and the run for the horizontal aspect. See
Figure 4.6.
Two 45º elbows may be used in place of one 90º elbow.
On 45º runs, one foot of diagonal is equal to 8-1/2 inch
(216 mm) horizontal run and 8-1/2 inch (216 mm) vertical
run. A length of straight pipe is allowed between two 45º
elbows. See Figure 4.6.
Figure 4.7 shows the vertical and horizontal off sets for
SLP elbows.
VERTICAL
Eff ective Length
SLP
Pipe
Inches
Millimeters
SLP4
4
102
SLP6
6
152
SLP12
12
305
SLP24
24
610
SLP36
36
914
SLP48
48
1219
SLP6A
3 to 6
76 to 152
SLP12A
3 to 12
76 to 305
Figure 4.6
Heat & Glo • COSMO32-IFT-B, COSMO36-IFT-B, COSMO42-IFT-B Installation Manual • 2619-980 Rev. G • 7/20
24
RUN
HORIZONTAL
Rise/Run
Inches
Millimeters
2-3/4
70
4-1/4
108
8-1/2
216
17
432
25-1/2
648
34
864
2-1/8-4-1/4
54-108
2-1/8-8-1/2
54-216
X
X
Vent
Type
Inches
Millimeters
SLP
5-1/4
X
Vent Type
SLP
Figure 4.7 Vertical and Horizontal Off set for DVP and SLP Elbows
Y
Y
Inches
Millimeters
133
11-3/8
289
X
X
Inches
Millimeters
11-1/4
286

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cosmo36-ift-bCosmo42-ift-b

Table of Contents