FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS

REMOVAL AND REPLACEMENT OF PARTS

COVERS AND PANELS

WARNING: DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
Top Front Cover
1.
The top front cover is secured with four (4)
screws, two on each side of cover. Remove
these screws then remove the cover from the
oven.
2.
Reverse the procedure to install.
Bottom Front Cover
1.
The bottom front cover is secured with four (4)
screws, two on each side of cover. Remove
these screws then remove the cover from the
oven.
2.
Reverse the procedure to install.
Control Panel
1.
Remove three (3) screws on the right side
which secure the control panel then pull the
panel away from the oven.
F25105 (December 2001)
NOTE: If the oven has a mechanical (KX type)
thermostat, it must be removed from the control
panel first, before removing the control panel.
2.
Disconnect the temperature probe leads from
the solid state temperature control.
3.
Unplug the wire harness connector to the
control panel components.
4.
Reverse the procedure to install.
Right Side Panel
1.
Remove the two screws near front of oven,
which secure the bottom front cover and control
panel.
2.
Remove the remaining seven screws securing
the right side panel.
3.
Pull the right side panel out at the bottom then
down to remove.
4.
Reverse the procedure to install.